183 research outputs found

    Measurement of the Luminosity in the ZEUS Experiment at HERA II

    Full text link
    The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same time the luminosity-measuring system of the ZEUS experiment was modified to tackle the expected higher photon rate and synchrotron radiation. The existing lead-scintillator calorimeter was equipped with radiation hard scintillator tiles and shielded against synchrotron radiation. In addition, a magnetic spectrometer was installed to measure the luminosity independently using photons converted in the beam-pipe exit window. The redundancy provided a reliable and robust luminosity determination with a systematic uncertainty of 1.7%. The experimental setup, the techniques used for luminosity determination and the estimate of the systematic uncertainty are reported.Comment: 25 pages, 11 figure

    Jakość życia pacjentów z cukrzycą typu 2 po wdrożeniu insulinoterapii — badanie prospektywne

    Get PDF
    Wstęp. W przypadku wielu pacjentów z cukrzycą typu 2, pomimo obserwowanego pogorszenia kontroli glikemii, dochodzi do opóźnienia intensyfikacji leczenia ze względu na bariery przed wdrożeniem insulinoterapii. Celem badania była ocena zmian w zakresie zależnej od zdrowia jakości życia wśród pacjentów z cukrzycą typu 2 po wdrożeniu insulinoterapii. Metody. Badaniem objęto 52 chorych z cukrzycą typu 2, dotychczas leczonych doustnymi lekami przeciwcukrzycowymi, u których zintensyfikowano leczenie poprzez dołączenie insuliny do dotychczas podawanych leków doustnych lub zastosowano monoterapię insuliną. Chorych poddano 8 (± 1,5)-miesięcznej obserwacji. Do pomiaru jakości życia zastosowano kwestionariusze: EQ-5D, DQL-BCI oraz DSC-R. Wyniki. Po okresie prospektywnej obserwacji stwierdzono istotną poprawę w zakresie jakości życia (EQ- -VAS, DSC-R). Wynik oceniany za pomocą kwestionariusza DQL-BCI nie uległ zmianie, jednakże szczegółowa analiza wykazała poprawę w zakresie satysfakcji z leczenia, wzrost poziomu wiedzy na temat cukrzycy, a także wzrost częstości odczuwania bólu związanego z leczeniem cukrzycy. Wnioski. Niniejsze badanie potwierdziło poprawę w zakresie zależnej od zdrowia jakości życia po wdrożeniu insulinoterapii, co powinno stanowić zachętę do podejmowania wczesnej intensyfikacji leczenia u pacjentów z pogorszeniem kontroli glikemii

    Jakość życia pacjentów z cukrzycą typu 2 po wdrożeniu insulinoterapii — badanie prospektywne

    Get PDF
    Introduction. In case of many patients with type 2 diabetes, despite deterioration of glycaemic control the moment of intensification of treatment is delayed because of barriers to initiating insulin therapy. The aim of the study was an evaluation of changes on health related quality of life (HRQoL) after intensification of the treatment among group of type 2 diabetes patients. Methods. The study involved 52 patients, treated so far by oral anti-diabetic drugs (OAD), for whom insulin was introduced. This group was exposed to 8 (± 1.5) months long observation. HRQoL was measured with questionnaires: EQ-5D, DQL-BCI and DSC-R. Results. After prospective observation, patients described significant improvement in QoL (EQ-VAS, DSC-R). DQL-BCI score remained unchanged, although detailed analysis showed improvement in treatment satisfaction, improvement in the level of knowledge about diabetes and increase in diabetes-related pain. Conclusions. Our study confirms the improvement in HRQoL after insulin therapy introduction. The results should encourage to early implementation of intensification of treatment.  Wstęp. W przypadku wielu pacjentów z cukrzycą typu 2, pomimo obserwowanego pogorszenia kontroli glikemii, dochodzi do opóźnienia intensyfikacji leczenia ze względu na bariery przed wdrożeniem insulinoterapii. Celem badania była ocena zmian w zakresie zależnej od zdrowia jakości życia wśród pacjentów z cukrzycą typu 2 po wdrożeniu insulinoterapii. Metody. Badaniem objęto 52 chorych z cukrzycą typu 2, dotychczas leczonych doustnymi lekami przeciwcukrzycowymi, u których zintensyfikowano leczenie poprzez dołączenie insuliny do dotychczas podawanych leków doustnych lub zastosowano monoterapię insuliną. Chorych poddano 8 (± 1,5)-miesięcznej obserwacji. Do pomiaru jakości życia zastosowano kwestionariusze: EQ-5D, DQL-BCI oraz DSC-R. Wyniki. Po okresie prospektywnej obserwacji stwierdzono istotną poprawę w zakresie jakości życia (EQ- -VAS, DSC-R). Wynik oceniany za pomocą kwestionariusza DQL-BCI nie uległ zmianie, jednakże szczegółowa analiza wykazała poprawę w zakresie satysfakcji z leczenia, wzrost poziomu wiedzy na temat cukrzycy, a także wzrost częstości odczuwania bólu związanego z leczeniem cukrzycy. Wnioski. Niniejsze badanie potwierdziło poprawę w zakresie zależnej od zdrowia jakości życia po wdrożeniu insulinoterapii, co powinno stanowić zachętę do podejmowania wczesnej intensyfikacji leczenia u pacjentów z pogorszeniem kontroli glikemii

    Luminometer for the future International Linear Collider - simulation and beam test results

    Get PDF
    LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated luminosity to be measured with a relative precision on the order of 10e-3, or 10e-4 when running in GigaZ mode. Luminosity will be determined by counting Bhabha scattering events coincident in the two calorimeter modules placed symmetrically on opposite sides of the interaction point. To meet these goals, the energy resolution of the calorimeter must be better than 1.5% at high energies. LumiCal has been designed as a 30-layer sampling calorimeter with tungsten as the passive material and silicon as the active material. Monte Carlo simulation using the Geant4 software framework has been used to identify design elements which adversely impact energy resolution and correct for them without loss of statistics. BeamCal, covering polar angles smaller than LumiCal, will serve for beam tuning, luminosity optimisation and high energy electron detection. Secondly, prototypes of the sensors and electronics for both detectors have been evaluated during beam tests, the results of which are also presented here.Comment: Technology and Instrumentation in Particle Physics 2011, Chicago, IL, USA. Presented June 11, 2011, and submitted to Physics Procedi

    Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up

    Get PDF
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.Comment: Paper published in Eur. Phys. J., includes 25 figures and 3 Table

    Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector

    Get PDF
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.Comment: 25 pages, 32 figures, revised version following comments from referee

    On Unbounded Composition Operators in L2L^2-Spaces

    Full text link
    Fundamental properties of unbounded composition operators in L2L^2-spaces are studied. Characterizations of normal and quasinormal composition operators are provided. Formally normal composition operators are shown to be normal. Composition operators generating Stieltjes moment sequences are completely characterized. The unbounded counterparts of the celebrated Lambert's characterizations of subnormality of bounded composition operators are shown to be false. Various illustrative examples are supplied

    ECFA Detector R&D Panel, Review Report

    Full text link
    Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 103^{-3} at the ILC and 102^{-2} at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.Comment: 61 pages, 51 figure

    Informacja dotycząca leczenia w relacji lekarz-pacjent

    Get PDF
    Introduction. Information connected with treatment, especially concerning potential side effects of medication, is an important part of physi­cian-patient relationship. Aim of the study. Evaluate patients opinions in area of information concerning medication obtained from physician. Material and methods. The study included 120 subjects (78 women and 42 men) at age between 19 and 87 years old. A method of proprietary questionnaire was used. Results. 78.3% of patients always or often are informed by physician about the aim of advised treatment, 93.3% are given information about the way of administration of medications. 25% studied persons always or often were aware of the potential adverse effects connected with treatment, 24.2% are never informed about this risk; 59.2% of patients would like to be informed about side effects of drugs, 47.5% of studied persons expect information on how medication works, this kind of knowledge is especially sought by younger patients. Conclusions. Physicians have informed the patients about adverse effects connected with treatment too seldom. This should encourage doctors to put more attention to this part of therapeutic process. Patients, especially younger ones, expect clear information about the treatment, particularly regarding the way a drug works and its potential side effects. Fulfillment of this expectations will result in respecting patient’s rights as well as will help avoid medical errors.Wstęp. Informacja dotycząca ordynowanego leczenia, w szczególności dotycząca działań niepożądanych leków, jest ważnym elementem właściwej relacji lekarz-pacjent. Cel pracy. Analiza opinii pacjentów o otrzymywanych informacjach o celu, działaniu i możliwych skutkach niepożądanych proponowanego leczenia oraz tego, jakich informacji pacjent oczekuje od lekarza. Materiał i metody. Badaniem objęto 120 osób (78 K i 42 M) w wieku od 19 do 87 lat (średnio 43,9 ± 17,2). Zastosowano metodę autorskiego kwestionariusza ankiety. Wyniki poddano analizie statystycznej. Wyniki. W trakcie wizyty w gabinecie 78,3% badanych zawsze lub często otrzymywało od lekarza informacje o celu zaleconego leczenia, 93,3% o sposobie dawkowania leków; 25% badanych zawsze lub często jes t uprzedzanych o działaniach niepożądanych leków, a kolejne 24,2% nie otrzymywało takiej informacji nigdy; 59,2% badanych chciałoby otrzymywać informacje o efektach ubocznych terapii, 47,5% pacjentów oczekuje także informacji o działaniu leków, w tej grupie przeważają pacjenci młodsi. Wnioski. Informacja dotycząca możliwych zdarzeń niepożądanych zalecanego leczenia przekazywana jest podczas wizyty lekarskiej zbyt rzadko. Fakt ten powinien skłonić lekarzy do zwrócenia większej uwagi na ten aspekt procesu terapeutycznego. Pacjenci, szczególnie w młodszych grupach wiekowych, oczekują jasno sprecyzowanych informacji o leczeniu, szczególnie o działaniu leku, w tym niepożądanym. Spełnienie tych oczekiwań będzie nie tylko realizacją praw pacjenta, ale także pozwoli lekarzowi uniknąć informacyjnego błędu medycznego

    Infrastructure for Detector Research and Development towards the International Linear Collider

    Full text link
    The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.Comment: 54 pages, 48 picture
    corecore